Our world is increasingly driven by vast sums of data stored in data centers.  Even moderately-sized companies must safely store hundreds  of data and their operations are critically dependent on the integrity, availability, and communication of this data throughout their facilities and their organization.  

Data centre managers keep the network and fiber optic cables that deliver this data neatly organized so that hardware systems can be efficiently traced, serviced, and moved and that any changes in the data capacity can easily be implemented.   For this reason, data centre managers frequently hire professional cable installers to organize and bundle their cables in a system called “structured cabling.   

 

 

 

STANDARDS FOR STRUCTURED CABLE INSTALLATIONS

Professional cable installers and technicians install these structured cable systems to meet the industry-standard ANSI/TIA 568.1-D.  Within this standard, there is a chapter focused on how these cables are to be bundled.  What it says is that plastic cable ties should not be used

Plastic cable ties can cinch a cable too tightly and alter the cable’s geometry and performance.  Also, when a move is needed, they need to be cut off with a wire cutter or other sharp tool, further endangering the cable bundle.  

Instead, the standard says that soft, conformable hook and loop material should be used to bundle the cables every three to six feet. 

VELCRO Brand Cable ties and Qwik tie continuous rolls are trusted by professional cable installers because they can easily be removed and repositioned without the use of tools and without danger to the cable. 

If a cable bundle is placed in an environmental air plenum (like an HVAC duct, suspended ceiling, or raised floor), then those cables and cable tie systems must meet the requirements of the NEC section 300.22 C and D.  These sections require the use of products that are fire retardant and have low smoke and heat release properties. 

V Tapes can supply you and your Installers with  fire retardant hook and loop Back2back tape,  which passes the fire retardant tests (UL 2043)  needed for meeting building code requirements. 

V Tapes has been supplying hook and loop bundling tapes to the medical, automotive, and general industrial markets for years. 

V Tapes  have an enormous  range of bundling tapes to provide the IT and telecommunications markets and to help professional cable installers confidently meet the needs of data center managers and the code requirements

 

 Unlike plastic cable ties that can constrict and damage cables,  V Tapes back-to-back self-engaging hook and loop is soft, flexible, and reusable to more safely support cable moves and additions. 

Our cable management products are professional grade and packaged in a variety of widths and lengths to meet the requirements of any size cable installation project.  With the addition of colours for coding and tracking networks. V Tapes manufacture Heavy Duty Cable Tripstop tape to meet cable Management requirements at all levels 

V Tapes bundling tapes can be used in a variety of applications including Data communications, Electrical wire harnesses, pro-Audio Visual & Security systems, Building plenum spaces, and medical/industrial. 

Samples of our Reusable Cable ties and Back-to-back tapes are available on request.